Tổng số lượt xem trang

Thứ Tư, 19 tháng 4, 2023

Elastography, vascularity measures improve TI-RADS performance

 

By Amerigo Allegretto, AuntMinnie.com staff writer

April 19, 2023

Researchers led by Dr. Leila Aghaghazvini from the Iran University of Medical Sciences in Tehran found that using these measures adds diagnostic value to traditional TI-RADS assessment of suspicious thyroid nodules, including higher sensitivity and specificity among other achievement marks.

"It would be advantageous to incorporate these criteria into TI-RADS risk stratification systems in order to reduce unnecessary fine-needle aspirations while keeping a high detection sensitivity for malignant tumors," Aghaghazvini and colleagues wrote.

Conventional ultrasound is typically used to detect thyroid cancer after physical examination and palpitation. However, Aghaghazvini et al noted that there is a lack of evidence that any particular ultrasound findings can predict thyroid cancer.

Specialists use TI-RADS to classify risk of malignancy based on ultrasound findings. But Aghaghazvini said that this does take a nodule's vascular or elastic characteristics into account. To address this knowledge gap, the team explored the value of adding vascularity and shear-wave elastography assessments to conventional TI-RADS assessments.

In an online poster presentation at the ARRS annual meeting
In an online poster presentation at the ARRS annual meeting, researchers led by Dr. Leila Aghaghazvini found that elastography and vascularity measures can help improve the performance of TI-RADS in assessing suspicious thyroid nodules. In these images, gray-scale features show a markedly hypoechoic thyroid nodule with irregular margins (TI-RADS 4), later confirmed as papillary thyroid cancer. (A) Elastography shows a mostly blue pattern. (B) Doppler sonography did not show any flow pattern. Images courtesy of the ARRS.

The study included 200 total thyroid nodules, assessed by conventional sonography to gather TI-RADS scores and important characteristics. The investigators used a 7.5 MHz probe to assess vascularity pattern and resistive index, performed quantitative elastography evaluations via color mapping, and calculated average and maximum velocities. They confirmed final diagnoses of all thyroid nodules via histopathology assessment or follow-up imaging.

The study found 37 TI-RADS 4 nodules, 15 of which were malignant, and 57 TI-RADS 5 nodules, 12 of which were malignant.

Overall, area under the curve (AUC) for TI-RADS assessment was 0.76. Adding elastography and resistive index measures to the mix translated to higher AUC values for TI-RADS 4 and 5 nodules.


AUC values of vascularity and elastography measures
MeasureTI-RADS 4TI-RADS 5
Resistive index0.930.96
Color map elastography grades0.890.85
Shear-wave elastography maximum velocity0.860.96
Shear-wave elastography average velocity0.820.97
Doppler grade0.80.8

The researchers also used a resistive index cutoff point of 0.6 in TI-RADS 4 nodules and found even higher values. This included AUCs of 0.93 for sensitivity, 1 for specificity, 0.97 for efficiency, 1 for positive predictive value, and 0.96 for negative predictive value.

When a cutoff point of 4.33 was used for shear-wave elastography average velocity, the researchers observed high diagnostic efficacy values. These included AUCs of 1 for sensitivity, 0.82 for specificity, 0.86 for efficiency, 0.6 for positive predictive value, and 1 for negative predictive value.

The study authors hope that these assessments will improve differentiation between malignant and benign thyroid nodules, Aghaghazvini said.

Thứ Tư, 29 tháng 3, 2023

Ultrasound, AI method diagnoses breast lumps without experts

 


By Amerigo Allegretto, AuntMinnie.com staff writer


March 27, 2023 -- Combining volume sweep imaging (VSI) for breast ultrasound with artificial intelligence (AI) could make way for rapid and automated diagnosis of breast lumps without a sonographer or a radiologist, suggest findings presented March 26 at UltraCon.

Marini and colleagues wanted to explore the potential for an automatic diagnostic system for evaluating breast lumps that would not require an expert sonographer or radiologist. It employed VSI performed by individuals without prior medical training using existing commercially available AI (S-Detect, Samsung).

Dr. Thomas Marini from the University of Rochester Medical Center presented findings suggesting that combined volume sweep imaging and artificial intelligence could accurately diagnose palpable breast lumps. Here, the combined method (right) is compared to standard of care (left), with both agreeing that the imaged area is possibly malignant. Image courtesy of Dr. Thomas Marini.